Electrician in toilet

According to the danger of electrical shock apartment can be divided into three categories – those that are safe, enjoy an increased risk and extremely dangerous. Restroom belongs to the third category, because it has a big number of risk factors – conductive covering, moisture, electric facilities with metal case. This state of things to think approximately and to do the bathroom a safe stay. It is organic that under maintenance toilet, you wish to arrange it as It is possible to more elegant and attractive, but it is another problem. First, you want to pay attention to the electrics, it must be as reliable. Because in addition to the fact that there is a risk of electric shock, it is likely that, because of poor wiring may cause a fire. However can prevent accidents that may occur in the restroom? In the first place, making renovation washroom should strictly adhere to the rules for electrical, however h2o is an excellent conductor of electricity. Second, all of the work on electrical setting, in the toilet want be implemented strictly adhering to all existing regulations. Which clearly spelled out all the restrictions on the mounting of an electric plant. However, for example, in the restroom should be kept to a minimum number of accessories, wiring, junction boxes, switches and sockets. Implementing maintenance lavatory electric work want be carried out how potential, rational, and connecting electricity to comply with the request set out in the EMP (“Electric Code”), specifications, building codes and state standards. Bathroom may be applied only specialized wiring items (fork RCD, RCD socket, etc.). Protection class of wiring accessories can not be lower II, and the degree of protection against h2o need be at least IP44. Each lavatory contains metal items (bath, sink, etc.) that are not related to electricity, but, nevertheless, may result in an accident at a time when the fuse blows. In order to avoid stress on these objects, they should be grounded, to avoid trouble. Grounding must be done even if the lavatory is not electrical. And with such equipment should take care of its grounding. In addition electrical rules defined and the minimum sizing of conductor that is used however the grounding jumpers (for the houses will be enough twisted wire with a cross section of 6 sq. Mm.). To provide aesthetic qualities, such wire can be laid in plaster, wall cavities, floors, etc. Do not lay the cable in the washroom, which has a rubber insulation, how in later a while it becomes brittle, which increases the risk of all sorts of problems, or even fire. Based on the above, it may be concluded that the electric work in the bathroom to be trusted only to professionals who specialize in this field. Therefore, by renovating a washroom, in any case, you want not rely on its own strength and superficial knowledge. Minor savings can lead to irreparable consequences.

Refurbishing flats

More Posts:

Комментирование и размещение ссылок запрещено.

Комментарии закрыты.

2017-08-17 1:49:06 - : /home/vita3125/domains/faarao.ru/public_html/133i58y269r14fh/cache_faarao_ru_1e.txt
2017-08-17 1:49:06 - : /home/vita3125/domains/faarao.ru/public_html/133i58y269r14fh/cache_faarao_ru_1e.txt